The Manhattan Bridge is a vital transportation link connecting Manhattan and Brooklyn, carrying hundreds of thousands of vehicles, trains, cyclists, and pedestrians daily. Subjected to constant vibration, heavy traffic loads, deicing salts, and a harsh marine atmosphere from the East River, the structure requires a robust corrosion protection system to ensure long-term structural integrity.
COMPANY
New York City Department of Transportation
PROJECT NAME
Manhattan Bridge Restoration
CONTRACTORS
Koch-Skanska
The Challenge
Why Wasser
Wasser Technology’s fast-curing formulations, exceptional corrosion resistance, and proven track record of longevity made us the clear choice foe this complex and high-stakes undertaking.
By reducing the curing time between coating layers, the project would progress more efficiently, limiting disruptions to traffic. And our coating’s high-performance durability would significantly extend the lifespan of the bridge’s structure and cables – reducing the need for additional maintenance down the line.
Surface Preparation
Cleaning- SSPC-SP10 Near White Blast Cleaning
- Power Wash and Hand Tool Cleaning
Bridge Structure and Tower Coating System Primer
Primer:- MC-Zinc (3-5 mils DFT)
- MC-Prepbond (1.2 - 2.5 mils DT)
Main Cable and Suspender Cable Coating System Primer
Primer:- MC-MioAluminum (1.5-2.0 mils DFT)
- MC-Ferromatic (3.0-5.0 mils DFT)
- MC-Luster (2-4 mils DFT)